On November 10, 2026 the New York City Department of Buildings (DOB) published final amendments to its energy code rules (1 RCNY 5000-01) in The City Record. The amendments align DOB's rules with the 2025 New York City Energy Conservation Code (2025 NYCECC), which applies to complete job applications filed on or after March 30, 2026. For glazing contractors, storefront installers and estimators in NYC and New Jersey, the changes affect what has to appear on drawings and submittals.
What changed
According to Building Enclosure, the amendments add requirements for documenting thermal bridges, additional efficiency credits, progress inspections and the Total System Performance Ratio (TSPR) as a compliance path. For fenestration:
- Door, window and skylight schedules must include U-factor, solar heat gain coefficient (SHGC) and visible transmittance (VT).
- Air-leakage sealing must be detailed, with testing or certification requirements identified on the drawings.
- Spandrel assemblies are treated as opaque, steel-framed walls. Configurations that differ from code assemblies may need thermal simulation, for example with THERM.
How fenestration is rated
Section C303.1.3 of the 2025 NYCECC requires U-factor, SHGC and VT for windows, doors and skylights to be determined under NFRC 100 and NFRC 200 by an accredited third party, and certified by a label on the product or a label certificate for the project. Products without a label get default values. For double-glazed windows and glass doors the default U-factor is 0.80 for metal frames and 0.65 for metal frames with a thermal break. Air infiltration must be tested to ASTM E283 at an independent lab, with a test less than five years old. DOB inspection guidance says installed fenestration is checked against the NFRC labels or the default tables.
In practice, an unlabeled storefront or window can be assigned a default U-factor far higher than most designs assume. That makes rated, thermally broken framing and documented glass important on NYC jobs.
Where IGCC and SGCC fit
The energy code rates the whole fenestration product. Glass certifications answer different questions on the same submittal. IGCC certification relates to the durability of insulating glass units, and SGCC certification relates to safety glazing. Architects in the Northeast often ask for both alongside the NFRC data, so ask your supplier early which listings apply to the units in your quote.
What to send with a quote request
- Window, door and storefront schedule with target U-factor, SHGC and VT.
- Framing type: thermally broken storefront, curtain wall or windows.
- Glass make-up (for example 1 in. IGU with low-e and argon, tempered or laminated lites) and any IGCC or SGCC requirement.
- Quantities, sizes, finish and delivery or pickup location.