Material supply for contractors, distributors & fabricators · USA & Canada
Pickup: Paterson, NJMon-Fri 8-5 ET+1 (201) 723-8804info@nordicnorden.com

Limiting Height Selector

Find the lightest stud from our range that works for your wall height, spacing, load and deflection limit, then add it to your quote.

Preliminary selection only. Final design and member selection are by the project’s engineer of record. Only studs from our product range are listed. Interior heights for traditional and EQ studs are the limiting heights published by our supplier; structural and curtain-wall heights are calculated by Nordic & Norden from our supplier’s published section properties. They do not replace the engineer’s design, the drawings or the building code.

Selector

Stud limiting height

Single-span studs, simply supported top and bottom, uniform lateral load.

Sections that work (preliminary)

Results need JavaScript.

Formulas & assumptions
  • Products: only studs we supply, traditional drywall studs (1-5/8" to 6", 18/30/33 mil), EQ drywall studs (25EQ and 20EQ) and structural C-studs (2-1/2" to 12", 33-97 mil). Every row is tagged with its data source: Supplier data or, for the one traditional size without a published data sheet (350S125-30), Industry (SSMA) generic.
  • Interior traditional and EQ studs at 5, 7.5 or 10 psf, L/120-L/360 and 12/16/24" o.c.: the height shown is the limiting height published by our supplier (per-product data sheets, AISI S220/S100; EQ: the supplier’s Intertek code compliance research report, fully braced table). Composite heights come from the same data sheets (ASTM C754 basis).
  • Structural studs (interior or curtain wall) and anything not covered by a published table are calculated. Load per stud w = pressure × spacing. Exterior: the design wind pressure you enter is an ASD component-and-cladding pressure; with the box ticked it is multiplied by 0.7 for the deflection check only, as IBC Table 1604.3 note f allows.
  • Bending: L = √(8 Ma ÷ w), Ma = lesser of Mal (local) and Mad (distortional buckling). Shear: L = 2 Va ÷ w. Deflection: L = ∛(384 E Ixe ÷ (5 w n)), E = 29,500 ksi. The stud is assumed fully braced (sheathing or bridging at no more than Lu).
  • Section properties for the calculation (Ixe, Mal, Mad, Va, Lu, Fy, weight) are our supplier’s published values (structural studs: Fy = 37 ksi as published). The method is the SSMA/AISI method and was checked against published tables (below).
  • Web crippling at the ends: the end reaction w·H/2 is checked against AISI S100 Eq. C3.4.1-1 (C-section, end one-flange, fastened, 1" bearing, Ω = 1.75). If exceeded, or h/t > 200, the stud needs an end web stiffener or clip; such sections are excluded unless you allow them. EQ studs: the published heights already include web crippling.
  • Max height is rounded down to the inch; sections are ranked by weight per foot, lightest first.
  • Not covered: axial load, deflection track and slip clips, headers and openings, multi-span studs, seismic out-of-plane forces, and walls carrying tile or stone weight. Ask your engineer.

How the results were checked

CheckScopeValuesResult
Interior, traditional studs, published table16 sections × 3 spacings × 9 load/limit cases432 valuesShown exactly as published (lookup)
Interior, traditional studs, composite16 sections × 3 spacings × 9 cases413 values (19 cells blank in the source)Shown exactly as published (lookup)
Interior, EQ studs, published evaluation-report table11 sections × 3 spacings × 9 cases297 valuesShown as published; 2 cells lowered to keep the table monotone
Our calculation vs. the supplier’s traditional-stud tablesame method as the structural and curtain-wall results432 valuesmean −0.6 %, mean abs. 1.1 %, 98.6 % within 5 %
Our calculation vs. SSMA tables (method check)45 interior + 63 curtain-wall SSMA sections5,751 valuesmean abs. 0.2 %, max 1.5 %, never above SSMA

Negative mean = our calculation is slightly conservative. The calculated results never exceed the SSMA values they were checked against; differences come from SSMA rounding to the nearest inch while this tool rounds down.

References: our supplier product data sheets, CFS framing catalog and the supplier’s Intertek code compliance research report; AISI S100, AISI S220 / S240; ASTM C645, C754, C955; SSMA Product Technical Guide (method check only). SSMA does not endorse this tool.