General reference tables for cold-formed steel framing designations, thickness and coatings.

Reading an SSMA designation

Steel framing members are identified with a four-part code used across the US industry. For example, 362S125-33 means:

PartExampleMeaning
Web depth362Web depth in 1/100 inch: 3.62 = 3-5/8"
StyleSMember type (see table below)
Flange width125Flange width in 1/100 inch: 1.25 = 1-1/4"
Thickness33Minimum base-metal thickness in mils (1 mil = 1/1000 inch)

Member style codes

CodeMember
SStud or joist with return lips (C-section)
TTrack (U-section without lips)
UU channel / cold rolled channel
FFurring (hat) channel
LAngle

Thickness reference

Thickness is ordered in mils. Gauge numbers are shown for reference only; the design thickness is used in calculations and the minimum thickness (95% of design) is the least thickness acceptable on delivery.

MilsRef. gaugeDesign thickness (in)Minimum thickness (in)Inside corner radius (in)
18250.01880.01790.0843
27220.02830.02690.0796
3020 (drywall)0.03120.02960.0781
3320 (structural)0.03460.03290.0764
43180.04510.04280.0712
54160.05660.05380.0849
68140.07130.06770.1069
97120.10170.09660.1525
118100.12420.11800.1863

Web depth and flange designators

DesignatorWeb depth
1621-5/8"
2502-1/2"
3503-1/2"
3623-5/8"
4004"
5505-1/2"
6006"
8008"
100010"
120012"
DesignatorFlangeTypical use
1251-1/4"Non-structural studs and track legs
1371-3/8"Studs (some sizes)
1621-5/8"Structural studs
2002"Structural studs, joists
2502-1/2"Structural studs, joists
3003"Heavy structural members

Common non-structural designations

Typical interior stud and track designations, 33 ksi, G40 minimum coating.

Web18 mil stud30 mil stud33 mil studTrack
1-5/8"162S125-18162S125-30162S125-33162T125-18/30/33
2-1/2"250S125-18250S125-30250S125-33250T125-18/30/33
3-1/2"350S125-18350S125-30350S125-33350T125-18/30/33
3-5/8"362S125-18362S125-30362S125-33362T125-18/30/33
4"400S125-18400S125-30400S125-33400T125-18/30/33
6"600S125-18600S125-30600S125-33600T125-18/30/33

EQ (equivalent gauge) studs and track use proprietary high-strength sections; specify the EQ designation (e.g. EQ 25, EQ 20) together with the web depth.

Common structural designations

Structural studs and track, 33 ksi (33-43 mil) or 50 ksi (54-97 mil), G60 coating, sized by the engineer of record.

Web1-5/8" flange stud2" flange stud2-1/2" flange studTrack legs
2-1/2"250S162-33 … -97250S200-33 … -97250S250-43 … -97250T125 / T150 / T200
3-5/8"362S162-33 … -97362S200-33 … -97362S250-43 … -97362T125 / T150 / T200
4"400S162-33 … -97400S200-33 … -97400S250-43 … -97400T125 / T150 / T200
5-1/2"550S162-33 … -97550S200-33 … -97550S250-43 … -97550T125 / T150 / T200
6"600S162-33 … -97600S200-33 … -97600S250-43 … -97600T125 / T150 / T200
8"800S162-33 … -97800S200-33 … -97800S250-43 … -97800T125 / T150 / T200
10"1000S162-33 … -971000S200-33 … -971000S250-43 … -971000T125 / T150 / T200
12"1200S162-33 … -971200S200-33 … -971200S250-43 … -971200T125 / T150 / T200

Galvanized coating designations

DesignationTotal both sides (oz/ft²), min. triple-spotMetric equivalentTypical use
G400.40Z120Interior non-structural framing
G600.60Z180Structural framing, exterior walls
G900.90Z275Severe exposure, coastal, specified jobs

These tables are general industry reference data for orientation only. Always follow the project drawings, specifications and the engineer of record. Mill test reports and ASTM C645 / A1003 compliance documents are available on request.